SPX29301

3A High Current, Low Dropout Voltage Regulator
Order Now

Overview

Information 3A High Current, Low Dropout Voltage Regulator
Output Option Fixed
VOUT (V) 5.0
VOUT Adj MIN (V) -
VOUT Adj MAX (V) -
IOUT (mA) 3000
VIN MIN (V) 2.8
VIN MAX (V) 16
IQ (µA) 37000
Accuracy (%) 1%
Vdrop (mV) 600
Output Noise (µVRMS) 260
PSRR (dB) -
Junction Temp Range (°C) -40 to 125
Package TO263-5
Features Enable,Power good,Current limit and thermal protection
Show more

The SPX29300/01/02 are 3A, highly accurate voltage regulators with a low dropout voltage of 600mV (typical) at 3A.

These regulators are specifically designed for low voltage applications that require a low dropout voltage and a fast transient response. They are fully fault protected against overcurrent, reverse battery and positive and negative voltage transients. On-Chip trimming adjusts the reference voltage to 1% initial accuracy.

The SPX29300 is offered in a 3-pin TO-263 package, the SPX29301 is offered in a 5-pin TO-263 while the SPX29302 is offered in a 5-pin TO-263 and 5-pin TO-220 package.

  • Adjustable output down to 1.25V
  • 1% output accuracy
  • Output current of 3A
  • Low dropout voltage of 450mV @ 3A
  • Extremely tight load and line regulation
  • Extremely fast transient response
  • Reverse battery protection
  • Zero current shutdown (5-pin version)
  • Error flag signal output for out of regulation state (5-pin version)

Documentation & Design Tools

Type Title Version Date File Size
Data Sheets 3A Low Dropout Voltage Regulator Data Sheet 2.2.3 May 2022 1.7 MB
Application Notes AN200, Downloading and Installing CAD Symbols and Footprints with Ultra Librarian April 2019 1.2 MB
Product Brochures Power Management Brochure R01 November 2024 2.4 MB
Symbols & Footprints SPX29301T5-L-5-0/TR CAD File (.bxl) September 2018 18.6 KB
Register for a myMxL account or Login to myMxL to view all Technical Documentation & Design Tools.

Quality & RoHS

Part Number RoHS | Exempt RoHS Halogen Free REACH TSCA MSL Rating / Peak Reflow Package
SPX29301T5-L-5-0/TR N Y Y Y Y L3 / 245ᵒC TO-263-5

Click on the links above to download the Certificate of Non-Use of Hazardous Substances.

Additional Quality Documentation may be available, please Contact Support.

Parts & Purchasing

Part Number Pkg Code Min Temp Max Temp Status Suggested Replacement Buy Now Order Samples PDN
SPX29301T5-1-8 TO-263-5 -40 125 OBS
SPX29301T5-1-8/TR TO-263-5 OBS
SPX29301T5-2-5 TO-263-5 OBS
SPX29301T5-2-5/TR TO-263-5 OBS
SPX29301T5-3-3 TO-263-5 -40 125 OBS
SPX29301T5-3-3/TR TO-263-5 OBS
SPX29301T5-5-0 TO-263-5 -40 125 OBS
SPX29301T5-5-0/TR TO-263-5 -40 125 OBS
SPX29301T5-L-1-8 TO-263-5 -40 125 OBS SPX29302U5-L
SPX29301T5-L-1-8/TR TO-263-5 -40 125 OBS SPX29302U5-L/TR
SPX29301T5-L-2-5 TO-263-5 -40 125 OBS SPX29302U5-L
SPX29301T5-L-2-5/TR TO-263-5 -40 125 OBS SPX29302U5-L/TR
SPX29301T5-L-3-3 TO-263-5 -40 125 OBS SPX29301T5-L-3-3/TR
SPX29301T5-L-3-3/TR TO-263-5 -40 125 OBS
SPX29301T5-L-5-0 TO-263-5 -40 125 OBS SPX29301T5-L-5-0/TR
SPX29301T5-L-5-0/TR TO-263-5 -40 125 Active Order
SPX29301U5-1-8 TO-220-5 OBS
SPX29301U5-2-5 TO-220-5 OBS
SPX29301U5-3-3 TO-220-5 -40 125 OBS
SPX29301U5-5-0 TO-220-5 OBS
SPX29301U5-L-1-8 TO-220-5 -40 125 OBS SPX29302U5-L
SPX29301U5-L-2-5 TO-220-5 -40 125 OBS SPX29302U5-L
SPX29301U5-L-3-3 TO-220-5 -40 125 OBS SPX29302U5-L
SPX29301U5-L-5-0 TO-220-5 -40 125 OBS SPX29302U5-L
Show obsolete parts
Part Status Legend
Active - the part is released for sale, standard product.
EOL (End of Life) - the part is no longer being manufactured, there may or may not be inventory still in stock.
CF (Contact Factory) - the part is still active but customers should check with the factory for availability. Longer lead-times may apply.
PRE (Pre-introduction) - the part has not been introduced or the part number is an early version available for sample only.
OBS (Obsolete) - the part is no longer being manufactured and may not be ordered.
NRND (Not Recommended for New Designs) - the part is not recommended for new designs.

Packaging

Pkg Code Details Quantities Dimensions
TO-220-5
  • JEDEC Reference: TS-001
  • MSL Pb-Free: n/a
  • MSL SnPb Eutectic: n/a
  • ThetaJA: 29.3ºC/W
  • Bulk Pack Style: Tube
  • Quantity per Bulk Pack: n/a
  • Quantity per Reel: n/a
  • Quantity per Tube: 50
  • Quantity per Tray: n/a
  • Reel Size (Dia. x Width x Pitch): n/a
  • Tape & Reel Unit Orientation: n/a
  • Dimensions: inch
  • Length: 0.370 max
  • Width: 0.415 max
  • Thickness: 0.190 max
  • Lead Pitch: 0.067
TO-263-5
  • JEDEC Reference: TO-263
  • MSL Pb-Free: L3 @ 245ºC
  • MSL SnPb Eutectic: n/a
  • ThetaJA: 31.2ºC/W
  • Bulk Pack Style: Tube
  • Quantity per Bulk Pack: n/a
  • Quantity per Reel: 500
  • Quantity per Tube: 50
  • Quantity per Tray: n/a
  • Reel Size (Dia. x Width x Pitch): 330 x 24 x 16
  • Tape & Reel Unit Orientation: Tab away from sprocket hole.
  • Dimensions: inch
  • Length: 0.380 max
  • Width: 0.420 max
  • Thickness: 0.190
  • Lead Pitch: 0.067

Notifications

Distribution Date Description File
07/17/2023 In 2023, MaxLinear will be converting all shipping labels for the parts noted from an EXAR format to MaxLinear’s label. During this transition customers may receive either label. This change affects only shipping and packing labels. This change will not affect the part number, part marking, manufacturing process or manufacturing sites. Only work in progress material will be converted. Existing inventory from MaxLinear’s warehouse, channel sales, distributor, and such, will not be converted. Hence, customers may experience receiving mixed shipments with both Exar and MaxLinear labels for some period until existing inventory of old labels is eventually cleared out. Situation is product to product with no predictable way to determine when all old labels will be exhausted. No change to product form, fit, function and reliability. ADDENDUM A: Fixed MBB label logo for DX204001 to MaxLinear logo. ADDENDUM B: Replaced ‘All other affected products outer box label’ with clearer pictures. Corrected Date Issued (from original PCN) issue date +90 days to August 30, 2023.
06/01/2023 In 2023, MaxLinear will be converting all shipping labels for the parts noted from an EXAR format to MaxLinear’s label. During this transition customers may receive either label. This change affects only shipping and packing labels. This change will not affect the part number, part marking, manufacturing process or manufacturing sites. Only work in progress material will be converted. Existing inventory from MaxLinear’s warehouse, channel sales, distributor, and such, will not be converted. Hence, customers may experience receiving mixed shipments with both Exar and MaxLinear labels for some period until existing inventory of old labels is eventually cleared out. Situation is product to product with no predictable way to determine when all old labels will be exhausted. No change to product form, fit, function and reliability.
06/01/2023 In 2023, MaxLinear will be converting all shipping labels for the parts noted from an EXAR format to MaxLinear’s label. During this transition customers may receive either label. This change affects only shipping and packing labels. This change will not affect the part number, part marking, manufacturing process or manufacturing sites. Only work in progress material will be converted. Existing inventory from MaxLinear’s warehouse, channel sales, distributor, and such, will not be converted. Hence, customers may experience receiving mixed shipments with both Exar and MaxLinear labels for some period until existing inventory of old labels is eventually cleared out. Situation is product to product with no predictable way to determine when all old labels will be exhausted. No change to product form, fit, function and reliability. ADDENDUM: Fixed MBB label logo for DX204001 to MaxLinear logo.
02/27/2018 Qualification of alternate assembly subcon, JCET.
07/11/2017 Product Discontinuation Notification
08/16/2016 Addition of an alternate qualified location, JCET.
07/26/2016 Product discontinuation notification. Discontinued.
12/22/2015 Alternate assembly site Addition of an alternate assembly supplier Nantong Fujitsu (China).
05/09/2011 Revised two mask layers. To improve the manufacturing control margin.
04/30/2010 Design and datasheet change. To improve product performance.
03/04/2009 Notice of Obsolescence Discontinued by Exar Corporation due to low market demand
02/28/2007 Product Obsolescence Letter and Discontinuation Notification. Discontinued.

FAQs & Support

Search our list of FAQs for answers to common technical questions.
For material content, environmental, quality and reliability questions review the Quality tab or visit our Quality page.
For ordering information and general customer service visit our Contact Us page.

Submit a Technical Support Question As a New Question

Yes. Try our Excel-based heat calculation spreadsheet ANP-03, Thermal Calculator
 
For further study, this spreadsheet is mentioned in the following helpful application note: ANP-02, Thermal Considerations for Linear Regulators 
  

Visit the product page for the part you are interested in.  The part's status is listed in the Parts & Purchasing section.  You can also view Product Lifecycle and Obsolescence Information including PDNs (Product Discontinuation Notifications).
 
To visit a product page, type the part into the search window on the top of the MaxLinear website.
 
In this example, we searched for XRA1201.  Visit the product page by clicking the part number or visit the orderable parts list by clicking "Orderable Parts". 
 
 
 

 

  

The Parts & Purchasing section of the product page shows the Status of all orderable part numbers for that product.  Click Show obsolete parts, to see all EOL or OBS products.